Fire Door Inspection Software - NFPA 80 Compliant

NFPA 80-compliant fire door inspection software. Digital checklists with photo documentation, gap measurements, hardware verification, and professional compliance reports - all from your mobile device.

Complete NFPA 80 fire door inspection support

NFPA 80 (Standard for Fire Doors and Other Opening Protectives) requires annual inspection of all fire-rated doors in commercial buildings. FireInspected provides the complete inspection workflow - no configuration needed.

What NFPA 80 requires you to inspect

  • Door clearances and gaps - Verify gaps around the door and at the bottom meet NFPA 80 tolerances (typically 1/8" for steel doors, 1/8" maximum under the door)
  • Latching hardware - Confirm the door latches positively and the latch throw is sufficient to secure the door in the frame
  • Self-closing device testing - Verify the door closer closes the door from any open position and latches without assistance
  • Door coordinator function - For pairs of doors, verify the active leaf closes before the inactive leaf in the correct sequence
  • Gasketing and edge seals - Inspect intumescent seals, smoke gaskets, and edge seals for damage, gaps, or missing sections

Additional NFPA 80 inspection points

  • Hinges and hardware - Check for loose screws, missing fasteners, bent hinges, or non-compliant field modifications
  • Glazing and vision panels - Verify fire-rated glazing beads, labels, and no cracks or damage to glass panels
  • Door labels - Confirm the fire-rated label is present, legible, and matches the door assembly specifications
  • Wall and frame conditions - Check for gaps between the frame and surrounding wall, which can compromise the fire barrier
  • Photo documentation of all deficiencies - Each deficiency is photographed and attached to the inspection record for AHJ review

Why fire door inspectors choose FireInspected

Fire door inspections are detail-intensive. FireInspected's digital checklist ensures you never miss an inspection point. Photos attach directly to each item. Reports generate instantly - professional documentation for building owners, fire marshals, and insurance audits.

Frequently asked questions

What NFPA standard covers fire door inspections?
NFPA 80 (Standard for Fire Doors and Other Opening Protectives) requires annual inspection of all fire-rated doors in commercial buildings. FireInspected provides the complete NFPA 80 inspection workflow.
How often do fire doors need to be inspected?
NFPA 80 requires annual inspections of all fire door assemblies. The door must be taken through its full range of motion, all hardware checked, and gaps verified within tolerances.
Can FireInspected handle fire door photos and measurements?
Yes. You can photograph each deficiency, record gap measurements in inches, document hardware condition, and attach everything to the inspection record for the AHJ report.

Other equipment types

Ready to stop using paper inspection tags?

Pre-built NFPA 10 forms, offline inspections, and professional PDF reports - from $49/month.

See How It Works

No credit card required. No annual contract. iOS + Android.